Governale Radiator Products - Gov-Boards
|
|
Narrow trim lines (2-1/2" wide) allows unit to blend with any decor. This unit can take the place of the base molding and can be painted to match your walls. View the specifics of each type here, if you have any questions, please give us a call.
Notes About Governale Gov-Board
- The Hot Water Ratings at 2000 lb. flow rate are limited to installations where the water flow rate through the GOV-BOARD is equal to or greater than 2000 lbs per hour (4 GPM)
- Where the water flow rate through the GOV-BOARD is not know, the rating at the standard flow rate of 500 lbs. (1 GPM) per hour must be used.
- Rating based on active length. Active length same as total length.
- Maximum allowable working pressure - 30 PSI, Water: 15 PSI, steam.
|
|
I=B=R Rating Data |
Flow Rate |
Steam Rate |
*Water Ratings
BTUH Per Linear Foot at Average Water Temp. Indicated |
Lbs/Hr |
Sq. Ft. |
BTU/Hr at 215° F |
170° F |
180° F |
190° F |
200° F |
210° F |
220° F |
230° F |
500 |
3.15 |
750 |
490 |
550 |
610 |
680 |
740 |
800 |
870 |
2000 |
3.15 |
750 |
520 |
580 |
640 |
720 |
780 |
850 |
920 |
I=B=R Ratings are determined from test made in accordance with the I=B=R Testing and Rating Code for baseboard type radiation,
including an allowance of 15% for heating effect permitted by the code.
"Pressure drop Ratings are available for all sizes directly from Governale Company, Inc." |
|
|
|
|